In the downdraft configuration of the 5100, there are 4 zones that are controlled by the program. The zone that is
active (open) is dependent on where the job is located in the cutting bed when Plate Origin is established.
Lincoln Electric recommends utilizing a filtration system rated for plasma cutting applications, with automatic filter
cleaning to extend life between filter servicing.
ZONE 4
ZONE 3
ZONE 2
ZONE 1
ZONE 1
Downdraft Operation
OUTPUT
ZONE 2
•
Each zone is controlled by pneumatic actuators to
open/close the dampers inside the table to allow for
proper air flow. The zones will open/close based on
where the parts are established on the cutting bed
and the plate origin.
•
If a part of a nest covers more than one zone, then
multiple zones will open to allow proper ventilation.
•
Output diameter connector ring is 14" diameter.
•
Output air flow required for Fume Extraction
•
61,800 ft
2
/hr or 1,750 m
•
Automatic Filter Cleaning, Pressure Controlled
ZONE 3
ZONE 4
19
2
/hr minimum
OUTPUT
User Guide