Lincoln Electric TORCHMATE 5100 User Manual page 49

Hide thumbs Also See for TORCHMATE 5100:
Table of Contents

Advertisement

The VMD can control OXY cutting torches with the OXY tab. This allows SET and CAPTURE time delays.
Oxy Controls
OXY:
Lifter:
Controls the lifter stations UP/DOWN position.
Up will raise the lifter.
Down will lower the lifter.
Pre-Heat:
Sets and alters the Pre-Heat time required for the OXY cutting.
OFF - Toggle to ON or OFF. This will activate the PREHEAT
DELAY time that is entered in the PREHEAT DELAY dialog.
EXTEND - Toggles between EXTEND and CAPTURE.
When EXTEND is PRESSED, this will extend the time until
released. It will then CAPTURE the time.
CONTINUE - Active or not. When pressed, it will turn on
the HIGH PRESSURE REGULATOR to start cutting.
Preheat
Delay:
Input for the delay for Preheat
Preheat
Timer:
Displays the total time elapsed
37