6.2.5 Problem starting or connecting the FlexPendant

6.2.5 Problem starting or connecting the FlexPendant
Description
The FlexPendant is not responding, either completely or intermittently.
No entries are possible, and no functions are available.
The FlexPendant starts but does not display the main interface.
xx1900000917
Required test equipment
Equipment needed for troubleshooting:
Equipment
Multimeter
Insulating gloves
Circuit diagram - OmniCore E10
Preparations
1
2
Continues on next page
176
Note
If protective gloves are used, these must be compatible with touchscreens when
using the FlexPendant.
Action
Make sure that the controller is switched on.
Wait 30 s - 1 min to enable start-up sequence.
Check the FlexPendant for errors and warnings.