6 Troubleshooting

6.2.1 No LEDs are lit on the controller

6.2.1 No LEDs are lit on the controller
Description
No LEDs at all are lit in the controller.
Required test equipment
Equipment needed for troubleshooting:
Equipment
Multimeter
Insulating gloves
Preparations
1
2
Recommended working procedure
If no LEDs are lit on the controller during start-up, use this procedure to troubleshoot
what might cause the problem.
Look at the following block diagram to understand how power is connected from
incoming and forward.
Block diagram
xx2100001552
Continues on next page
168
Action
Make sure that the controller is switched on.
Wait 30 s - 1 min to enable start-up sequence.
Check the FlexPendant for errors and warnings.
DANGER
Troubleshooting on the controller while powered on must be performed by personnel
trained by ABB or by ABB field engineers.
AC input
Power inlet
PE
X0