5.3.2 Replacing the incoming mains connector

Location
The illustration shows the location of the incoming mains connector in the controller.
xx2100001328
Required spare parts
Spare part
Harness AC input with SW
Connector AC power inlet
Required tools and equipment
Equipment
Standard toolkit
ESD protective wrist band
Product manual - OmniCore E10
3HAC079399-001 Revision: C
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore E10 via myABB Business Portal,
www.abb.com/myABB.
© Copyright 2019-2022 ABB. All rights reserved.
5.3.2 Replacing the incoming mains connector
Article number
Note
3HAC075416-001
Harness-Mains connection
3HAC077706-001
Mating connector for Power inlet
Article number
Note
-
Content is defined in section
Standard toolkit for controller on
page
-
5 Repair
202.
Continues on next page