5 Repair

5.2.2.1 Replacing the small fans

5.2.2.1 Replacing the small fans
Removing the small fan
Preparations
1
2
3
Removing the small fan
1
Continues on next page
124
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
28.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
41.
Remove the top cover of the controller.
Action
Disconnect:
G1/G2.X1
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx2100001295
Removing the controller top cover on
page
120.
Note/Illustration
xx2100001330
Product manual - OmniCore E10