Status Monitoring - Jetter JetWeb JetMove 203-230 User Manual

Table of Contents

Advertisement

JetMove 203-230
8
The amplifier LEDs indicate the operating status of the digital servo amplifier.
Jetter AG

Status Monitoring

JetMove 203-230 - LEDs
LED
Colour
5V
Green
L1
Yellow
L2
Yellow
L3
Yellow
Note!
The 7-segment display of the output stage indicates the operating and fault
conditions of the digital servo amplifier JetMove 203-230. The various display
modes are set by the Motion Setup. Mode 0 (default) is used for normal operation
and mode 1 for commissioning.
JetMove 203-230 - 7-Segment Display
Mode 0: Normal Operation
Display
0
NOT READY TO BE
SWITCHED ON
1
INITIALIZATION
COMPLETE
2
READY TO BE SWITCHED
ON
3
SWITCHED ON
4
OPERATION_ENABLED
State
is lit
Logic module voltage is OK
is lit
Axis is standing still (speed = 0)
is lit
A voltage of 24 V is applied to the input of
the positive limit switch (LIMIT+).
is lit
A voltage of 24 V is applied to the input of
the negative limit switch (LIMIT-).
State
Initialisation of amplifier functions
Initialization completed. Safe state. Is
achieved after initialising and after
acknowledging errors.
The drive controller can be switched
on.
Drive controller has been disabled by
software command.
The drive controller can be switched
on.
DC link monitoring is activated.
The drive controller has been
enabled.
Meaning
Meaning
63