Jetter JetWeb JetMove 203-230 User Manual page 29

Table of Contents

Advertisement

JetMove 203-230
Jetter AG
Parameters
Protection class
Dielectric strength
Insulation
Protective earth
connection
Overvoltage category
EMI Emitted Interference
Parameters
Enclosure
Alternating network
current
Important!
This is a product of restricted availability according to IEC/EN 61800-3.
This module can cause radio interferences in residential areas. In this
case, the user must take adequate measures to prevent this.
Additional line filters can be helpful here. See "Line filter" on page 36.
Operating Parameters
Electrical Safety
Value(s)
I
Protective network conductor and
network logics: 1.7 kV, 5 s
Protective network conductor and
network logics: > 1 MOhm at 500 V
12 V, 10 A, 0.1 Ohm
III
Operating Parameters
Value(s)
Frequency band
30 - 230 MHz, limit 30 dB (µV/m)
in 30 m
Frequency band
230 - 1000 MHz, limit 37 dB
(µV/m) in 30 m
(First surroundings, restricted
availability)
Frequency band:
0.15 - 0.5 MHz, limit 79 dB (µV)*
0.5 - 30 MHz, limit 73 dB (µV)*
* Measuring by means of the
quasi-peak detector
(First surroundings, restricted
availability)
Standard
Specification(s)
Referred to
DIN EN 50178
DIN EN 50178
DIN EN 60204-1
DIN EN 50178
DIN EN 60204-1
DIN EN 50178
DIN VDE 0110-1
UL 508C
Standard
Specification(s)
Referred to
DIN EN 61800-3
DIN EN 61800-3
29