Assignment And Specification - Jetter JetWeb JetMove 203-230 User Manual

Table of Contents

Advertisement

7 Description of Connections
7.2.2
Specification of the connector for terminal X62
Specification of the motor cable
Cable shielding
Connection of the motor to the digital servo amplifier JetMove 203-230 has to be
done following the wiring diagram below. (Connection of the brake is optional)
Fig.9: Connection of motor lines
48

Assignment and specification

4-pin connector (type PC 4/ 4-ST-7.62)
Rewirable core cross-section: 0.25 - 4 mm
Bladed screw-driver: 0.6 x 3.5 x 100 mm
Stud torque of terminal blocks: 0.5 Nm - 0.6 Nm
Cable size: 4 * 0.75 mm²
Material: Copper
Temperature class: 60 °C
Stripping length of the cores: 6 mm
Bootlace ferrules are recommended
Braided copper shield of 80% coverage
X10
24 V
0 V
Strain relief
of the
JM203-230
PE
U2
V2
W2
X 62
2
2
The shield is extensively
connected with the
metallised connecor
housing
PE
green / yellow
core 1
phase 1
core 2
phase 2
core 3
phase 3
JetWeb
Free-wheeling
diode, if not
Brake +
integrated into the
Brake -
motor
Motor
Jetter AG

Advertisement

Table of Contents
loading

Table of Contents