9 Diagnostics
Error
Type of Error
Number
F 05
Current overload
F 06
Overload internal
ballast resistor
F 07
Shutdown
threshold for
device temperature
F 08
Shutdown
threshold for motor
temperature
F 09
Encoder error
F 10
Overspeed
F 11
Current overrange
66
Error Message Table JetMove 203-230
Description
The output current
has been greater
than 2.5 x the rated
current
The ballast resistor
has been
overloaded
The amplifier has
reached the
maximum
temperature
The motor has
reached the
maximum
temperature
Encoder breakage
or initialization error
The actual shaft
speed has
exceeded a value of
1.25 x maximum
speed
A current
temporarily too high
has been detected
Effect
Error Correction
– Immediate
– Check cable and
pulse disable
motor for a short
circuit
– Check current control
parameters. If
necessary, correct
parameters
– Acknowledge failure
– Immediate
– Let the drive
pulse disable
controller cool down
– After cooling down,
acknowledge failure
– Reduce regeneration
power
– Immediate
– Let the drive
pulse disable
controller cool down
– After cooling down,
acknowledge failure
– Reduce power of
drive system
– Immediate
– Let the motor cool
pulse disable
down
– After cooling down,
acknowledge failure
– Reduce the power of
the drive
– Immediate
– For extended
pulse disable
diagnostics purposes
use motion setup
– Check the encoder
line and all plug-in
connections
– Acknowledge failure
– Immediate
– Check motor and
pulse disable
encoder connections
– Check speed
controller parameters
If necessary, modify
parameters
– Acknowledge failure
– Immediate
– Reduce K
pulse disable
current controller by
10 to 20 %
– Acknowledge failure
JetWeb