Jetter JetWeb JetMove 203-230 User Manual page 14

Table of Contents

Advertisement

1 Safety Instructions
Fig.1: Double earthing
14
BUS-IN
6
9
X18
BUS-OUT
9
6
X19
ENCODER
9
6
X61
Important!
Do not loop an earth-leakage current breaker into the mains power
supply.
Using an earth-leakage current breaker (FI) looped into in the mains power
supply is not possible.
If, in spite of this, an earth-leakage current breaker is installed, it will switch off
the digital servo amplifier JetMove 203-230, although there is no fault.
When a leakage current screen needs to be installed in the JetMove 203-230, an
isolating transformer must be used.