9 Diagnostics
Error
Type of Error
Number
F 20
Undervoltage DC
link voltage
F 21
Overvoltage DC
link voltage
F 22
The drive has
stalled
F 23
Tracking error
F 24
Error in 24 V
(combined
supply voltage
with F 01)
F 25 - F 27
Internal supply
(combined
error
with F 01)
F 29
Mains power too
high
68
Error Message Table JetMove 203-230
Description
The DC link voltage
is less than the
minimum value
The DC link voltage
has exceeded the
maximum value
The drive could not
overcome the n = 0
threshold within the
time limit specified
by the parameter
"blocking-triping
time"
The tracking error
has exceeded the
limit defined in the
parameter "tracking
error limit" for the
time specified in
"tracking window
time"
External 24 V supply
was lower than 18 V
one or more internal
supply voltages has
fallen below their
limit
The average mains
power is too high
Effect
Error Correction
– Stop with
– Check the voltage of
emergency
the power line
stop ramp
– Check the parameter
"U
– Acknowledge failure
– Stop with
– Check the voltage of
emergency
the power line
stop ramp
– In generator
operation reduce
braking power
– Acknowledge failure
– Immediate
– Eliminate the cause
pulse disable
of stalling
– Acknowledge failure
– Stop with
– Check the drive
emergency
mechanism
stop ramp
– Check steepness of
acceleration/
deceleration ramps
and amplifier
parameters in relation
to the parameters
"tracking error limit"
and "tracking window
time"
– Acknowledge failure
– Immediate
– Check external power
pulse disable
supply
– Acknowledge failure
– Immediate
– Note the number of
pulse disable
error
– Return the amplifier
for repair
– Immediate
– Acknowledge failure
pulse disable
– Reduce the average
load of the motor