Parameters
Connected load
Supply fluctuations
Parameters
Operating conditions
Storage conditions
(units within packing)
Transport conditions
(units within packing)
Pollution degree
Corrosion immunity /
Chemical resistance
Operating Parameters
Connected Load
Value(s)
Switching device:
3 * AC 230 V, 50 / 60 Hz
(AC 195 V through AC 265 V)
Logic part:
DC 24 V, SELV / PELV <= 0.6 A
(DC 20 V through DC 30 V)
Speed of changing the frequency:
2 %/s max.
Voltage imbalance:
2 % max.
Voltage dips:
3 ms max.
Operating Parameters
Environment
Value(s)
Temperature: 0 °C to +45 °C
(+45 °C to +55 °C: Derating 2.5 %/
K)
Air humidity:
5 % to 85 %, non-condensing
Temperature: -25 °C to +55 °C,
Maximum fluctuation: 20 K/h
Air humidity:
5 % to 95 %, non-condensing
Maximum storage period:
< 1 year without restrictions
Temperature: -25 °C to +70 °C
Air humidity:
5 % to 95 %, non-condensing
2
No special protection against
corrosion. Ambient air must be
free from higher concentrations of
acids, alcaline solutions, corrosive
agents, salts, metal vapours, or
other corrosive or
electroconductive contaminants
Standard
Specification(s)
Referred to
Standard
Specification(s)
Referred to
DIN EN 50178
DIN EN 50178
DIN EN 50178
DIN EN 50178
-