Jetter JetWeb JetMove 203-230 User Manual page 31

Table of Contents

Advertisement

JetMove 203-230
Jetter AG
EMI Immunity to Interference
Parameters
Burst (fast transients)
EMI Immunity to Interference
Measuring and Control Circuits in Process
Parameters
Burst (fast transients)
Guided radio
disturbances
EMI - Immunity to Interference
Parameters
Burst (fast transients)
Operating Parameters
Power Interfaces
Value(s)
Test voltage 2 kV
Repetition rate 5 kHz
Capacitive interference
Criterion B
(Second surroundings, restricted
availability)
Operating Parameters
Environments
Value(s)
Test voltage 2 kV
Repetition rate 5 kHz
Capacitive interference
Criterion B
(Second surroundings, restricted
availability)
Frequency 0.15 - 80 MHz
Test voltage 10 V
AM 80 % with 1 kHz
Criterion A
(Second surroundings, restricted
availability)
Operating Parameters
Signal Interfaces
Value(s)
Test voltage 1 kV
Repetition rate 5 kHz
Capacitive interference
Criterion B
(Second surroundings, restricted
availability)
Standard
Specification(s)
Referred to
DIN EN 61800-3
DIN EN 61000-4-4
Standard
Specification(s)
Referred to
DIN EN 61800-3
DIN EN 61000-4-4
DIN EN 61800-3
DIN EN 61000-4-6
Standard
Specification(s)
Referred to
DIN EN 61800-3
DIN EN 61000-4-4