Jetter JetWeb JetMove 203-230 User Manual page 67

Table of Contents

Advertisement

JetMove 203-230
Error
Type of Error
Number
F 12
Earth fault
F 13
Internal checksum
(combined
error
with F00)
F 14
Internal
(combined
communication
with F 00)
error
F 15
The hardware
enable is missing
F 16
Power input over
current
F 17
Trip of software
limit switch
F 18
Trip of hardware
limit switch
Jetter AG
Error Message Table JetMove 203-230
Description
One or more phases
of the motor cable or
inside the motor
have been short-
circuited to earth
An internal
checksum error has
occurred
An internal
communication error
has occurred
The software enable
is given without a
hardware enable
The current at the
power input was to
high
Actual position is
outside the range of
software limits and
software limit
switches are active
One hardware limit
switch was activated
Effect
Error Correction
– Immediate
– Check the motor
pulse disable
cable and the motor
– Acknowledge failure
– Immediate
– Switch the 24 V
pulse disable
supply off and on
again
– If the error occurs
repeatedly, return the
amplifier for repair
– Immediate
– Switch the 24 V
pulse disable
supply off and on
again
– If the error occurs
repeatedly, return the
amplifier for repair
– Immediate
– Disable the drive by
pulse disable
means of the
software
– Acknowledge failure
– Immediate
– Check input voltage
pulse disable
– Reduce mechanical
power of the motor
– Acknowledge failure
– Stop with
– Check destination
max. current
position
(torque)
– Acknowledge failure
– Run axis back inside
the range of software
limits (software limit
switches will be active
automatically by
entering this range)
– Stop with
– Check destination
max. current
position
(torque)
– Check reference
position
– Acknowledge failure
– Run axis back inside
the range of hardware
limits (software limit
switches will be active
automatically at
leaving the switch)
9.1 Error Messages
67

Advertisement

Table of Contents
loading

Table of Contents