Jetter JetWeb JetMove 203-230 User Manual page 36

Table of Contents

Advertisement

5 Technical Data
36
Electrical Specification
Cross-sectional area of supply-
cable conductors
Cross-sectional area of motor
supply cable
Line filter
Voltage supply of processor logics
(demands on power supply
module)
Internal ballast resistor
Residual voltage
Leakage current
Enable (E),
Reference switch (R);
Limit switch RH (L+), and
limit switch LH (L+);
Input (Inp)
2
Min. 0.75 mm
2
Min. 0.75 mm
, 50 m length max.
(if you need greater lengths, please contact
Jetter AG)
Line filter ensuring unrestricted EMC
residential environment to DIN EN 61800-3.
The following filters can be applied with
input circuits:
– NEFB 10332 with I
= 16 A
r
– NEFB 10333 with I
= 25 A
r
– NEFB 10334 with I
= 36 A
r
See "Note 3!" on page 37.
24 V DC (20 .. 30 V)
0.6 A
The voltage output of the power supply
unit must comply with the SELV or PELV
type.
Resistor: 200
Continuous power: 100 W
Maximum capacity: internally limited to
1 kW at 0.6 s (warning and error
message)
To avoid hazard of electrical shock wait at
least 5 minute after switching-off the digital
servo amplifier before attempting to pull out
the plug or remove this unit (refer to
page 17).
> 3.5 mA
See "DANGER resulting from electric
shock!" on page 38.
DC 20 V ... 30 V related to the controller
potential
7.5 mA max. input current per input
See chapter 7.5 "Digital Inputs, Logic
Power Supply", page 58
JetWeb
in a
Jetter AG

Advertisement

Table of Contents
loading

Table of Contents