22-13
Purpose
Adjustment/Setting/Operation data check
Function (Purpose) Used to check the operating time of the
process section (OPC drum, DV unit, toner
cartridge) and the fusing unit
Section
Process
Operation/Procedure
The number of prints and the number of rotations in the process
section are displayed.
Item/Display
MAINTENANCE ALL
FUSING ROLLER
PRESSURE ROLLER
SEPARATE PAWL(U)
CLEANING FELT
TC UNIT
OZONE FILTER
DEVE CTRG(K)
DRUM CTRG(K)
MAIN CHARGER(K)
DRUM BLADE(K)
TONER CTRG(K)
22-14
Purpose
Adjustment/Setting/Operation data check
Function (Purpose) Used to display the use status of the toner
cartridge.
Section
Process
Operation/Procedure
The status of the toner cartridge is displayed.
Display item
Content
1
TONER (K)*
Toner number counter (K)
2
LARGE*
Toner number counter
(K LARGE)
2
SMALL*
Toner number counter
(K SMALL)
*1: The sum total of LARGE/SMALL is displayed. For the remaining amount, it is common to LARGE/SMALL.
*2: The remaining amount is not displayed.
22-18
Purpose
Adjustment/Setting/Operation data check
Function (Purpose) Used to display the user data delete history.
Section
Operation/Procedure
The date and time of the user data delete are displayed.
Display item
Item name
Date
START
Year/month/day/hour/min.
END
Year/month/day/hour/min.
Content
Maintenance counter (Total)
Fusing roller
Pressure roller
Upper separate pawl
Cleaning felt
Transfer unit
Ozone filter
Developer cartridge K
Drum cartridge K
Main charger K
Drum blade K
Toner cartridge K
Accumulated No. of
installed cartridges (Unit)
INSTALL
0 - 510
0 - 255
Content
Delete history (Date and time
of operation start)
Delete history (Date and time
of operation end)
MX-M316N SIMULATION 6 – 19
Counter
RPM
Max. 8
Not displayed
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Not displayed
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Max. 8
Accumulated No. of near
near end (Unit)
NN END
0 - 510
0 - 255
Number of
Life meter
use days
(Unit: +/-1%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
0 - 999
0 - 100(%)
Accumulated No. of
Remaining quantity
end (Unit)
(Unit: %)
END
RESIDUAL
0 - 510
0 - 255
75-100%
Number of
remaining
days
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
0 - 365
Not displayed
0-25%
25-50%
50-75%

Advertisement