Download Print this page

Sharp MX-M356N Service Manual page 120

Hide thumbs Also See for MX-M356N:

Advertisement

43-10
Purpose
Setting
Function (Purpose) Used to set the postcard feed cycle
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
Item
Display
A
POSTCARD CYCLE
43-20
Purpose
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item
Display
A
HL_UM READY LL
B
HL_US READY LL
C
HL_UM PLAIN BW LL
D
HL_US PLAIN BW LL
E
WARMUP FUMON HL_US T
LL
F
WARMUP FUMOFF LL
G
WARMUP END TIME LL
H
HL_UM THIN LL
I
HL_US THIN LL
J
HL_UM HEAVY LL
K
HL_US HEAVY LL
L
HL_UM LABEL LL
M
HL_US LABEL LL
N
HL_UM OHP LL
O
HL_US OHP LL
P
HL_UM ENV LL
Q
HL_US ENV LL
R
HL_UM E-STAR LL
S
HL_US E-STAR LL
T
HL_UM PRE-JOB LL
U
HL_UM WARMUP_120L LL
V
HL_US WARMUP_120L LL
W
LO_WARMUP_TIME_LL
X
HL_UM WARMUP_120H LL
Y
HL_US WARMUP_120H LL
Z
HI_WU_TIME_LL
AA
HI_WU_FM_ON_TMP_LL
AB
HI_WU_END_TIME_LL
AC
HI_WU_JOB_SET_TMP_LL
AD
HI_WARMUP_BORDER_LL
AE
LO_WU_JOB_SET_TMP_LL
AF
JOBEND_FUMON_TIME LL
AG
HI_WU_JOB_SET_TMP 2
LL
AH
LO_WU_JOB_SET_TMP 2
LL
Setting
Content
range
Postcard feed cycle
1 - 99
Correction value for TH_UM set value in ready standby under LL environment
Correction value for TH_US set value in ready standby under LL environment
Correction value for black and white plain paper TH_UM set value under LL environment
Correction value for black and white plain paper TH_US set value under LL environment
Correction value for fusing motor previous rotation start TH_UM set value under LL environment
Fusing motor prior rotation completion time under LL environment
Correction value for warm-up complete time under LL environment
Correction value for thin paper TH_UM set value under LL environment
Correction value for thin paper TH_US set value under LL environment
Correction value for heavy paper TH_UM set value under LL environment
Correction value for heavy paper TH_US set value under LL environment
Correction value for label paper TH_UM set value under LL environment
Correction value for label paper TH_US set value under LL environment
Correction value for OHP-TH_UM set value under LL environment
Correction value for OHP-TH_US set value under LL environment
Correction value for envelope TH_UM set value under LL environment
Correction value for envelope TH_US set value under LL environment
Correction value for preheating TH_UM set value under LL environment
Correction value for preheating TH_US set value under LL environment
Correction value for the set value of TH_UM when restoring from preheating under LL environment
Correction value for TH_UM set value in Warm-Up at 120 degree Cor below under LL environment
Correction value for TH_US set value in Warm-Up at 120 degree C or below under LL environment
Correction value for O, P applying time (timer from Ready complete) under LL environment
Correction value for TH_UM set value in Warm-Up at 120 degree C or above under LL environment
Correction value for TH_US set value in Warm-Up at 120 degree C or above under LL environment
Correction value for R, S applying time (timer from Ready complete) under LL environment
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha degree C or above under LL
environment
Correction value for Warm-Up completion time in Warm-Up at alpha degree C or above under LL
environment
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or above
under LL environment
Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or below
under LL environment
Correction value for the after rotation time when completing a job under LL environment
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or above
under LL environment
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or below
under LL environment
MX-M316N SIMULATION 6 – 41
Default
value
50
Content
Setting
Default
range
value
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50

Advertisement