27-4
Purpose
Setting
Function (Purpose) Used to set the initial call and toner order
auto send. (FSS function)
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Item/Display
A
FSS MODE
NEB1
NEB2
NFB1
NFB2
B
RETRY_BUSY
C
TIMER(MINUTE)_BUSY
D
RETRY_ERROR
E
TIMER(MINUTE)_ERROR
F
FAX RETRY
G
TONER ORDER
EMPTY
TIMING(K)
NEAR_END
5%
10%
15%
20%
25%
30%
35%
40%
45%
50%
H
TEMP HISTORY CYCLE
I
LOG OUTPUT CAPACITY(PCU)
J
TONER ORDER TIMING
CONTROL
27-5
Purpose
Setting
Function (Purpose) Used to set the machine tag No. (This func-
tion allows the host computer to check the
machine tag No.) (FSS function)
Section
Communication (RIC/MODEM)
Operation/Procedure
1)
Enter the password (max. 8 digits) with 10-key.
The entered password is displayed on the column of "NEW".
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2)
Press [SET] key.
Content
Set the FSS MODE
Exclusive for send in NE-B mode
Send/Receive in NE-B mode
Exclusive for send in NE-F mode
Send/Receive in NE-F mode
Resend number setting when busy
Resend timer setting (minute) when busy
Resend number setting when error
Resend timer setting (minute) when error
Resend number setting when FAX initial connection
Toner order auto send
Empty
timing setting (K)
Near end
5%
10%
15%
20%
25%
30%
35%
40%
45%
50%
Frequency of acquiring the temperature and humidity history
Log output capacity
Toner order timing
Toner order alert send at the fixed
control
toner remaining quantity.
Toner under alert send when
presuming the toner
consumption.
MX-M316N SIMULATION 6 – 33
Setting
range
0 - 3
0 - 15
1 - 15
0 - 15
1 - 15
0 - 15
0 - 11
1 - 1440
0 - 50
0 - 1
0 - 50
27-6
Purpose
Setting
Function (Purpose) Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
0
Allow (Default)
1
Inhibit
2)
Press [OK] key.
The set value in step 1) is saved.
Default
Remarks
value
0
1
1
2
For convenience
stores
3
For convenience
stores
2
0: No retry
3
1
0: No retry
1
2
Unit: Number of times
0
6
1
2
3
4
5
6
7
8
9
10
11
60
Unit: min.
30
Unit: [KB]
0
0
1

Advertisement

loading