53-8
Purpose
Adjustment
Function (Purpose) Used to adjust the document lead edge ref-
erence and the RSPF mode document
scan position.
Section
Operation/Procedure
Select an adjustment item with [AUTO] [MANUAL] key.
AUTO: Document lead edge reference (RRCA) adjustment
(Auto adjustment)
1)
Set a sheet of black paper of A4 or 11"x 8.5" on the document
table.
2)
Press [EXECUTE] key. (The adjustment is performed and the
adjustment value is saved.)
53-9
Purpose
Adjustment
Function (Purpose) Set dirt detection for SPF scanning posi-
tion.
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item/Display item, Details of display
A
DIRT_ALARM_SET
B
SIDEA_SCAN_POSIION _SET_START
C
SIDEA_SCAN_POSITION_SET_JOB
D
SIDEA_SCAN_POSITION_LV
E
OC_DIRT_LV
F
SIDEA_DIRT_ALARM_LV
G
SIDEA_DIRT_SHADING_SET
53-10
Purpose
Adjustment/Setup
Function (Purpose) SPF dirt detection execution.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
Item/Display
SPF SIDEA
SPF front surface dirt detection position (main scan
position 1 to 8) "-": No dirt, A"*": Dirt
OC
OC surface dirt detection position (main scan
position 1 to 8) "-": No dirt, "*": Dirt
SPF front surface optimum scan position detection setting (when
starting)
SPF front surface optimum scan position detection setting (After a
job)
SPF front surface optimum scan position detection level setting
OC dirt level setting
SPF front surface dirt alarm level setting
SPF back surface dirt alarm level setting
SPF front surface streak delete shading setting
Content
MX-M316N SIMULATION 6 – 63
Item/Display
Content
MEASUREMENT
Document lead edge
DISTANCE
measurement distance
RRCA
Document lead edge
reference position
MANUAL: RSPF mode document scan position adjustment
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
Item/Display
A
ADJUST
RSPF mode document scan
VALUE
position adjustment (Scanner
stop position adjustment)
* When the adjustment value is increased, the scanner stop posi-
tion in the RSPF mode is shifted to the right.
* When the adjustment value is changed by 1, the position is
shifted by 0.1mm.
Content
Setting
range
0-255
(0.1mm unit)
0 - 99
Setting
Content
range
1 - 99
Setting
range
OFF
0 - 1
0
ON
1
OFF
0 - 1
0
ON
1
WEAK
0 - 1
0
MIDDLE
1
STRONG
2
WEAK
0 - 2
0
MIDDLE
1
STRONG
2
WEAK
0 - 2
0
MIDDLE
1
STRONG
2
WEAK
0 - 2
0
MIDDLE
1
STRONG
2
OFF
0 - 1
0
ON
1
Default
value
-
50
Default
value
5
Default
value
0
(OFF)
0
(OFF)
1
(ON)
1
(MIDDLE)
1
(MIDDLE)
1
(MIDDLE)
1
(ON)