Download Print this page

Sharp MX-M356N Service Manual page 121

Hide thumbs Also See for MX-M356N:

Advertisement

* WARMUP END TIME LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
* Items C/D: Correction of "-5" is made for item C and Item D in the case of B5 size
Code descriptions
TH_UM
Fusing thermistor main (Front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
* Correction value: (-49 - +49), Input value: Actual input value (1 - 99)
Correction value
-49
-25
Input value
1
25
43-22
Purpose
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item
Display
A
HL_UM PLAIN BW DUP LL
B
HL_US PLAIN BW DUP LL
C
PLAIN BW DUP APP CNT LL
D
HL_UM HEAVY BW DUP LL
E
HL_US HEAVY BW DUP LL
F
HEAVY BW DUP APP CNT LL
* PLAIN BW DUP APP CNT LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
Code descriptions
TH_UM
Fusing thermistor main (Front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
* Setting value: Target value (-49 - +49), Input value: (Actual input value) 1 - 99
Setting value
-49
-25
Input value
1
25
-5
0
+5
+25
45
50
55
75
Correction value for the upper TH_UM black and white plain paper duplex under the LL
environment
Correction value for the upper TH_US black and white plain paper duplex under the LL
environment
Correction value for applying number of sheets in black and white plain paper duplex under LL
environment
Correction value for the upper TH_UM set value of black and white heavy paper duplex under the
LL environment
Correction value for the upper TH_US set value of black and white heavy paper duplex under the
LL environment
Correction value for applying number of sheets in black and white heavy paper duplex under LL
environment
-5
0
+5
+25
45
50
55
75
MX-M316N SIMULATION 6 – 42
HL_UM
Heater lamp main (Heat roller for front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
+49
99
Content
HL_UM
Heater lamp main (Heat roller for front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
+49
99
Setting
Default
range
value
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50

Advertisement