(4) Reinstall and update procedures of the HDD storage
Operation Manual data
1)
Obtain the Operation Manual data.
Download the Operation Manual data from the utility menu on the
web site (Tech-DS home page).
Copy the downloaded files to the USB device without changing
the file hierarchy.
To upload to the complex machine, files of "**_pdf_fax.idx" and
"**_pdf.idx" and "version.txt" as well as the Operation Manual data
(**.pdf) are required. When the downloaded files are copied with-
out changing the file hierarchy, these files also are copied.
NOTE: When data are uploaded from the USB memory to the
HDD, if there are some data in the HDD, the files in the
memory are compared with the files in the HDD and only
the files which satisfy the following conditions are written
into the HDD.
• The file size is different.
• The time stamp is different.
• The file exists only in the USB memory.
CAUTION: The data backed up with SIM56-2 must not be installed to
another machine. If installed, the adjustment data will be
overwritten and a trouble may be generated.
2)
Enter the SIM49-3 mode.
3)
Insert the USB memory into the machine.
• When the USB memory is not inserted, "INSERT A STORAN-
GEE-MANUAL STORED ON" is displayed. When [OK] button is
pressed, the screen shifts to the folder select menu 1.
4)
Select the folder of the Operation Manual data. (The screen shifts
to the Operation Manual data install menu.)
The current version and the update version are displayed.
5)
Press [EXECUTE] button.
[EXECUTE] button is highlighted, and [YES] and [NO] buttons are
changed from gray-out to active display.
6)
When [YES] button is pressed, the selected Operation Manual is
installed.
When install is completed, "COMPLETE" is displayed. In case of
an abnormality, "ERROR" is displayed.
(5) Watermark data reinstall and update procedures
1)
Obtain the watermark data.
Download the watermark data from the utility menu on the web
site (Tech-DS home page).
Copy the downloaded files to the USB device without changing
the file hierarchy.
NOTE: When data are uploaded from the USB memory to the
2)
Enter the SIM49-5 mode.
3)
Insert the USB memory into the machine.
• When the USB memory is not inserted, "INSERT A STORAN-
GEE-MANUAL STORED ON" is displayed. When [OK] button is
pressed, the screen shifts to the folder select menu 1.
4)
Select the folder of the watermark data. (The screen shifts to the
watermark data install menu.)
The current version and the update version are displayed.
5)
Press [EXECUTE] button.
[EXECUTE] button is highlighted, and [YES] and [NO] buttons are
changed from gray-out to active display.
6)
When [YES] button is pressed, the selected watermark data are
installed.
When install is completed, "COMPLETE" is displayed. In case of
an abnormality, "ERROR" is displayed.
MX-M316N OTHERS 13 – 6
HDD, if there are some data in the HDD, the files in the
memory are compared with the files in the HDD and only
the files which satisfy the following conditions are written
into the HDD.
• The file size is different.
• The time stamp is different.
• The file exists only in the USB memory.