1
51
1
51-1
Purpose
Adjustment
Function (Purpose) Adjust the ON/OFF timing of the transfer
current.
Section
Operation/Procedure
1)
Select an adjustment target item with scroll key on the touch
panel.
51-2
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the contact pressure (deflec-
tion amount) on paper by the main unit and
the RSPF registration roller. (This adjust-
ment is performed when there is a consid-
erable variation in the print image position
on the paper or when paper jams frequently
occur.)
Section
Operation/Procedure
1)
(When RSPF model)
Select a target adjustment mode with [SIDE1] or [SIDE2] or
[ENGINE] keys.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the set value with 10-key.
Mode
Display/Item
SIDE1
A
NORMAL_PLAIN_HIGH
B
NORMAL_PLAIN_LOW
C
NORMAL_THIN_HIGH
D
NORMAL_THIN_LOW
E
RANDOM_PLAIN_HIGH
F
RANDOM_PLAIN_LOW
G
RANDOM_THIN_HIGH
H
RANDOM_THIN_LOW
SIDE2
A
NORMAL_PLAIN_HIGH_1
B
NORMAL_PLAIN_LOW_1
ENGINE
A
TRAY1(S)
B
TRAY1(L)
C
TRAY2(S)
D
TRAY2(L)
E
MANUAL PLAIN PAPER (S)
2)
3)
Item
A
B
4)
RSPF front surface document deflection amount adjustment value
(Normal/Plain paper/HIGH)
RSPF front surface document deflection amount adjustment value
(Normal/Plain paper/LOW)
RSPF front surface document deflection amount adjustment value
(Normal/Thin paper/HIGH)
RSPF front surface document deflection amount adjustment value
(Normal/Thin paper/LOW)
RSPF front surface document deflection amount adjustment value
(Random/Plain paper/HIGH)
RSPF front surface document deflection amount adjustment value
(Random/Plain paper/LOW)
RSPF front surface document deflection amount adjustment value
(Random/Thin paper/HIGH)
RSPF front surface document deflection amount adjustment value
(Random/Thin paper/LOW)
RSPF back surface document deflection amount adjustment value 1
(Normal/Plain paper/HIGH)
RSPF back surface document deflection amount adjustment value 1
(Normal/Plain paper/LOW)
Main unit cassette 1 (Upper stage)/deflection adjustment value
(Plain paper/Small size)
Main unit cassette 1 (Upper stage)/deflection adjustment value
(Plain paper/Large size)
Main unit cassette 2 (Lower stage)/deflection adjustment value
(Plain paper/Small size)
Main unit cassette 2 (Lower stage)/deflection adjustment value
(Plain paper/Large size)
Manual feed tray/deflection adjustment value (Plain paper/Small size)
MX-M316N SIMULATION 6 – 61
Enter the set value with 10-key.
Press [OK] key. (The set value is saved.)
When the adjustment value is decreased, the transfer ON/OFF
timing for the paper is advanced. When the adjustment value
is increased, the timing is delayed. When the adjustment value
is changed by 1, the timing is changed by about 2ms. The set-
ting range is -98 - +98ms.
Display
TC ON
Transfer current ON timing setting
TIMING
TC OFF
Transfer current OFF timing
TIMING
setting
Press [OK] key. (The set value is saved.)
Content
Default
Content
value
50
50
Setting
range
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
-
1 - 99
LT size (216mm)
1 - 99
or less
LT size (216mm)
1 - 99
or above
LT size (216mm)
1 - 99
or less
LT size (216mm)
1 - 99
or above
LT size (216mm)
1 - 99
or less
Default
value
50
50
50
50
50
50
50
50
50
50
25
25
50
50
50

Advertisement