Mode
Display/Item
ENGINE
F
MANUAL PLAIN PAPER (L)
G
MANUAL HEAVY PAPER (S)
H
MANUAL HEAVY PAPER (L)
I
MANUAL OHP
J
MANUAL ENV
K
MANUAL LBL
L
ADU PLAIN PAPER (S)
M
ADU PLAIN PAPER (L)
N
DESK (S)
O
DESK (L)
Note on "Large size" and "Small size"
Small size: The paper length in the transport direction is shorter than the LT size (216mm).
Large size: The paper length in the transport direction is longer than the LT size (216mm).
Adjustment value
When the adjustment value is increased, the warp amount is increased. When the adjustment value is decreased, the warp amount is
decreased.
(When the adjustment value is changed by 1, the stop timing is changed by 0.1mm.)
51-9
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the ON/OFF timing of the
separation voltage.
Section
Operation/Procedure
1)
Select an adjustment target item with scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item
Display
A
DHV ON
Separation voltage ON/OFF
timing adjustment
B
DHV OFF
Separation voltage OFF timing
adjustment
When the adjustment value is increased, the timing is delayed.
When the adjustment value is changed by 1, the timing is changed
by about 4ms. The setting range is -196 - +196ms.
53
53-6
Purpose
Adjustment
Function (Purpose) Used to adjust the detection level of the
RSPF document width.
Section
Operation/Procedure
1)
Open the RSPF paper feed guide to the maximum width.
2)
Press [EXECUTE] key.
The maximum width detection level is recognized.
3)
Open the RSPF paper feed guide to the A4R width.
4)
Press [EXECUTE] key.
The A4R width detection level is recognized.
5)
Open the RSPF paper feed guide to the A5R width.
Manual feed tray/deflection adjustment value (Plain paper/Large size)
Manual feed tray/deflection adjustment value
(Heavy paper/Small size)
Manual feed tray/deflection adjustment value
(Heavy paper/Large size)
Manual feed tray/deflection adjustment value (OHP)
Manual feed tray/deflection adjustment value (Envelope)
Manual feed tray/deflection adjustment value (Label paper)
ADU/deflection adjustment value
(Plain paper/Small size)
ADU/deflection adjustment value
(Plain paper/Large size)
DESK/deflection adjustment value
(Plain paper/Small size)
DESK/deflection adjustment value
(Plain paper/Large size)
Setting
Default
Content
range
1 - 99
1 - 99
MX-M316N SIMULATION 6 – 62
Content
6)
Press [EXECUTE] key.
The A5R width detection level is recognized.
7)
Open the RSPF paper feed guide to the minimum width.
8)
Press [EXECUTE] key.
The minimum width detection level is recognized.
When the above operation is nor performed normally, "ERROR" is
displayed and. When the above operation is completed normally,
"COMPLETE" is displayed.
1
TRAYVOLMAX
2
TRAYVOLA4R
3
TRAYVOLA5R
4
TRAYVOLMIN
value
50
50
53-7
Purpose
Function (Purpose) Used to adjust the RSPF document size
Section
Operation/Procedure
1)
Select an adjustment target item with scroll key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
A
AD_MAX
B
AD_P1
C
AD_P2
D
AD_MIN
LT size (216mm)
or above
LT size (216mm)
or less
LT size (216mm)
or above
-
-
-
LT size (216mm)
or less
LT size (216mm)
or above
LT size (216mm)
or less
LT size (216mm)
or above
Tray size volume maximum value
Tray volume A4R size adjustment value
Tray volume A5R size adjustment value
Tray size volume minimum value
Adjustment/Setup
width sensor.
Item/Display
Max. width position
A4R width position
A5R width position
Min. width position
Setting
Default
range
value
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
Setting
Default
range
value
0 - 1023
84
0 - 1023
509
0 - 1023
808
0 - 1023
961

Advertisement