EXECUTE
Adjustment completed
Abnormal end
EXECUTE
or INTERRUPT
MX-M316N ADJUSTMENTS AND SETTINGS 5 – 3
4)
Close the front cabinet.
5)
When [EXECUTE] key is pressed, [EXECUTE] key is high-
lighted (in black) and the developer adjustment is started. (The
adjustment is automatically performed for 3 minutes.)
6)
When the developer adjustment is completed, [EXECUTE] key
returns to the normal state (in white), and the developer adjust-
ment value is displayed.
CAUTION: If the operation is interrupted within 3 minutes, the
adjustment result is not reflected.
When [EXECUTE] key is pressed during the operation,
the operation is stopped and [EXECUTE] key returns to
the normal display.
If [EE-EU] or [EE-EL] is displayed, setting of the refer-
ence toner density control value is not completed nor-
mally.
Troubleshoot the cause, remove the cause, and per-
form setting again.
Error
Error name
display
EE-EL
EL abnormality
Sensor output level than 78
EE-EU
EU abnormality
Sensor output level over 178
7)
Cancel SIM25-2 with [CA] key.
CAUTION: When not replacing the developer, do not execute
SIM25-2.
Detail of error