Download Print this page

Sharp MX-M356N Service Manual page 104

Hide thumbs Also See for MX-M356N:

Advertisement

: '15/Aug.
1
25-2
Purpose
Setting
Function (Purpose) Used to make the initial setting of toner
density when replacing developer. (Auto-
matic adjustment)
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
Toner cartridges must be installed to execute this setting (Toner
1
density control reference value setting)
Because of the structure of this machine, if SIM25-2 is executed
without the toner cartridges installed, the waste toner transport pipe
of the process UN may be locked.
1)
Press [EXECUTE] key.
The developing motor rotates and the toner density sensor makes
sampling of the toner density, displaying the detected level.
After stopping the developing motor, it is set as the reference toner
density control level.
CAUTION: When the above operation is interrupted on the way, the
reference toner concentration level is not set. Also when
error code of EE-EL or EE-EU is displayed, the refer-
ence toner density level is not set normally.
CAUTION: Do not execute this simulation except when new devel-
oper is supplied. If it is executed in other cases, under-
toner or overtone may occur, causing a trouble.
Item/Display
AT DEVE ADJ
Automatic development
adjustment value
Display during execution of the simulation
Item/Display
TCS
Toner sensor output value
Error content
Display
Error name
EE-EL
EL abnormality
EE-EU
EU abnormality
25-4
Purpose
Adjustment/Setting/Operation data check
Function (Purpose) Used to display the operation data of the
toner correction quantity. (Not used in the
market.)
Section
Process
Operation/Procedure
The operation data of the toner supply quantity are displayed.
Item/Display
TONER DEN_LT
Current toner density sensor output
value (final value)
TONER DEN_ST
Current toner density reference
value display (the value including all
the correction values)
AUTO DEVE
Automatic development adjustment
value
ALL
All correction reference value
LIFE
Life correction value
ENV
Environment correction value
DUPLEX
Duplex correction value
PRINT RATE
Print ratio correction value
AREA
Area correction value
Display
Content
range
1 - 255
Content
Error content
Sensor output level less than 78
Sensor output level over 178
Display
Content
-128 - 127
-128 - 127
-128 - 127
-128 - 127
-128 - 127
MX-M316N SIMULATION 6 – 25
Item/Display
AUTO DEVE AREA
CURRENT AREA
26
26-1
Purpose
Function (Purpose) Used to set Yes/No of installation of the Job
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
This setting is required to use the Job separator.
A
0
1
26-2
Purpose
Function (Purpose) Used to set the paper size of the paper feed
Default
value
128
Section
Operation/Procedure
Select a paper size and a weight system to be changed.
Item
LEGAL SET
G/LBS SET
Destination
U.S.A
CANADA
INCH
JAPAN
AB_B
EUROPE
U.K.
AUS.
AB_A
CHINA
range
1 - 255
1 - 255
1 - 255
1 - 255
Content
Area in the auto development
adjustment
Current area
Setting
separator.
Paper exit
Item/Display
YES
Job separator provided
NO
Job separator not provided
Setting
tray. (When the paper size is changed, this
simulation must be executed to change the
paper size in software.)
Paper feed
Setting value
0
1
2
0
1
Setting value
LEGAL SET
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
8.5 x 14
Display
range
-128 - 127
-128 - 127
Content
Content
8.5 x 14
8.5 x 13.4
8.5 x 13.5
GRAM
LBS
G/LBS SET
LBS
LBS
LBS
GRAM
GRAM
GRAM
GRAM
GRAM
GRAM
GRAM

Advertisement