Clear Robot Failure (Input) - Denso RC5 Interface Manual

Robot controller
Table of Contents

Advertisement

4.4.9 Clear Robot Failure (Input)

Robot status
Operation preparation ON
start (input)
Clear robot
failure (input)
Motor power
ON (input)
Robot failure
(output)
Servo ON
(output)
Input Conditions and Operation of Clear Robot Failure Signal
(1) Function
The robot can recover from a stopped state, resulting from a robot failure
by turning ON (shorted) the operation preparation start signal with this
signal ON (shorted).
(2) Terminal number
No.25 of connector CN8.
NOTE: Operation preparation start signal is inputted through No. 8 of
connector CN8.
(3) Usage
The signal is used to clear an error that brought the robot to a stop.
(4) Input conditions and operation
 When a robot failure occurs, clear the error display on the teach
pendant and the external output ERROR NUMBER to ready the robot
to operate.
‚ When the Clear robot failure signal is turned ON (shorted), other input
signals (MOTOR POWER ON, CAL EXECUTION, SP100 and SWITCH
EXT MODE), which are to be used in combination with the operation
preparation start signal, will be ignored.
To turn ON the power to the motor after a robot failure is cleared, turn
OFF (open) the Clear robot failure signal after turning OFF the Robot
failure signal (output) as shown below.
ƒ Input the Clear robot failure signal before (1 msec. or more) the
operation preparation start signal.
Stop due to
a robot failure
OFF
1 ms.
or more
ON
required
OFF
ON
OFF
ON
OFF
ON
OFF
Clear robot failure
Motor power ON
50 ms. or more required