Denso RC5 Interface Manual page 71

Robot controller
Table of Contents

Advertisement

[ 4 ] Status Area
This section describes the usage of the status area (16 bits, output) and of
status area odd parity (output).
(1) Function
The signal outputs the result of I/O command processing to the external
device.
(2) Terminal numbers
Nos. 17 to 32 of connector CN10.
(3) Usage
The signal is used to execute an I/O command and obtain the result of the
PLC.
(4) ON conditions
 When processing of the I/O given is completed, the status
corresponding to the command will be set.
‚ "ON" represents the bit value = 1.
"OFF" represents the bit value = 0.
"Parity bit" is odd parity.
ƒ Input 1 or 0 as the parity bit so that the total of 1s existing in the
command area and status area parity will be odd.
The status area counts even commands, which do not require any data
area, in a parity calculation.
„ Parity can be set valid or invalid with a parameter. When parity is
invalid, no parity check will be performed.
(5) OFF conditions
 The signal will be turned OFF when the strobe signal is turned OFF.
‚ If the strobe signal is turned OFF, before command processing is
completed, the status signal will be output and then turned OFF within
100 msec.
51

Advertisement

Table of Contents
loading

Table of Contents