Auto Mode (Output) - Denso RC5 Interface Manual

Robot controller
Table of Contents

Advertisement

4.2.2 Auto Mode (Output)

Auto mode output
(1) Function
The signal outputs to the external device that the robot is in the auto
mode.
(2) Terminal number
No.4 of connector CN10.
(3) Usage
Starting the program from the external device requires an SWITCH EXT
MODE input, a PROGRAM NO. SELECT input and a PROGRAM START
input. The signal is used to confirm that the robot is in the auto mode.
(4) ON conditions
The signal will be output when the robot enters the auto mode under the
following conditions.
 The mode selector switch of the operating panel or the teach pendant
is set to AUTO.
(5) OFF conditions
The signal will be turned OFF under the following conditions.
 When the mode selector switch of the operating panel is set to
MANUAL or the teach pendant is set to MANUAL or TEACH CHECK.
‚ When Enable Auto OFF is input.
(Caution: The signal will not be turned OFF in the pendantless state
described in the OPTIONS MANUAL, Chapter 1, Subsection 1.3.3.)
Caution: The signal will not be turned OFF with INSTANTANEOUS
STOP, STEP STOP or CYCLE STOP.
The Mode selector switch of the operating panel or the teach pendant is
set to AUTO.
SWITCH AUTO MODE and OPERATION PREPARATION START are
input from the external device.
The mode selector switch of the operating panel is set to
MANUAL or that of the teach pendant is set to MANUAL or
TEACH CHECK.
Enable Auto OFF is input.
Auto Mode Output
71

Advertisement

Table of Contents
loading

Table of Contents