Diagnostic Commands
Setting Bit Error Rate (BER) Limit
This command is used to set BER high and low limit. The limits for high and low BER are
inter-dependent. High BER cannot be less than low BER and low BER cannot be more than
high BER at any given time.
1.
From the Diagnostic menu, use the
BER Limit
Figure 5-17: Diagnostics Screen—Set BER Limit
The Set Ber Limit screen appears (see Figure 5-18). The high and low BER values define a
hysteresis function. The valid range for BER values is 0-65535. Initially, the range for high
BER will be 450-65535, and the range for low BER will be 0-800.
The factory default values: High BER value = 800 x 10
2.
Enter the value for the high BER rate press:
3.
Enter the value for the low BER rate press:
5-18
and press:
(see Figure 5-17).
<Return>
6880494G55-O
RF-Conductor! Controller NIU Remote Configuration
to position the cursor to the left of the listing
<tab>
-6
, Low BER value = 450 x 10
.
<Return>
.
<Return>
Set
-6
May 1998