RF-Conductor! Controller NIU Remote Configuration
Changing Maintenance IDs
Each transmitter is assigned a maintenance ID. This maintenance ID is used when the RF-C!
initiates a maintenance cycle. A maintenance cycle consists of commands that tell a
transmitter programmed with maintenance ID "x" to key-up and send the maintenance data.
The maintenance cycle starts with ID 0 and ends with ID 63 (depending on the number of
maintenance IDs supported). Multiple transmitters will usually be assigned the same
maintenance ID in a system.
Note:
This command can be executed only in device addressing mode for a single transmitter.
1.
From the SuperStream menu, use the
Change Maintenance ID
Figure 4-6: SuperStream Menu—Change Maintenance ID
The Change Maintenance ID screen appears (see Figure 4-7).
2.
Enter the Maintenance ID and press
May 1998
to position the cursor to the left of the listing
<tab>
and press:
(see Figure 4-6).
<Return>
Valid values are 0-63.
<Return>.
6880494G55-O
SuperStream Commands
4-7