Click
to reset pattern scan path
Click
to delete the selected pattern scan
To delete the pattern scans, go to Configuration → PTZ → Clear Config, check Clear All
NOTE:
Patterns, and click Save.
8.5.

Set Linear Scan

The device can perform auto scan in setting area for fire source detection.
Steps
1. Go to Configuration → PTZ → Linear Scan.
2. Select the camera channel.
3. Zoom in and zoom out the camera to the appropriate zoom ratio, and click Save Ratio.
NOTE:
Click Enable Saved Ratio to set the camera to the saved zoom ratio.
4. Check Enter Area Settings.
5. Set the left/right/up/down limits with the PTZ control panel, and click
6. Optional: Click Clear to delete the saved scan area.
7. Click Save.
8. Click Call Linear Scan to start linear scan, and click Stop Linear Scan to stop linear scan.
NOTE:
When setting the linear scan area, make sure the target area is included in both the optical
channel and the thermal channel.
8.6.

Set Limit

The device can move only within the limited range.
Steps
1. Go to Configuration → PTZ → Limit.
2 . Select Limit Type.
Manual Stops: The movement range limit when you control the device manually.
Scan Stops: The movement range limit when the device scans automatically.
Scan limit is supported by only devices that have the scan function.
3. Click Set and set limits according to the prompt on the live image.
4. Optional: Click Clear to clear the limit settings of the selected mode.
UM DS-2TD6267-75C4L/W 042221NA
to confirm settings.