Steps
Note
This function is only supported by certain models.
1. Click to show the PTZ control panel, and click
2. Select one pattern scan path that needs to be set.
3. Click
to start recording pattern scan.
4. Click PTZ control buttons as demands.
Note
Recording stops when the space for pattern scan is 0%.
5. Click
to complete one pattern scan path settings.
6. Click
to call pattern scan.
Stop pattern scan.
Reset pattern scan path.
Delete the selected pattern scan.
Note
If you need to delete all the pattern scans, go to Configuration → PTZ → Clear Config , and
check Clear All Patterns, and click Save.

9.5 Set Linear Scan

The device can perform auto scan in setting area for fire source detection.
Steps
1. Go to Configuration → PTZ → Linear Scan .
2. Select the camera channel.
3. Zoom in and zoom out the camera to the appropriate zoom ratio, and click Save Ratio.
Note
Click Enable Saved Ratio to set the camera to the saved zoom ratio.
4. Check Enter Area Settings.
5. Set the left/right/up/down limits with the PTZ control panel, and click
6. Optional: Click Clear to delete the saved scan area.
7. Click Save.
8. Click Call Linear Scan to start linear scan, and click Stop Linear Scan to stop linear scan.
.
50
to confirm settings.