Advanced Configuration - HIKVISION DS-2TD6267-75C4L/W User Manual

Thermal & optical bi-spectrum ptz network camera
Hide thumbs Also See for DS-2TD6267-75C4L/W:
Table of Contents

Advertisement

DS-2TD6267-75C4L/W Thermal & Optical Bi-Spectrum PTZ Network Camera User Manual
2. Click the up and down arrow to adjust the patrol sequence.
3. Click Save.
5.3.

Advanced Configuration

Go to Configuration → VCA → Advanced Configuration and configure the parameters.
Detection Parameters
• Detection Sensitivity: The higher the sensitivity, the easier the target will be detected.
• Background Update Rate: If a detected target remains in the monitoring scene for a certain time, the
system will count the target as the background automatically. The greater the value, the faster the
target will be counted as the background.
• Minimum Target Size: The system will filter out objects smaller than the minimum target size.
• Displacement Constraint for Target Generation: The higher the value, the slower the target is
generated, and the higher the analysis accuracy.
• Optical-axis Movement: Check this function when the target moves in the direction of the camera's
optical -axis.
NOTE:
When the target is far from the device and the movement is not clear, enable this function
to check the move direction.
• Single Alarm: The system sends alarm only once for one target triggering. Otherwise, the alarm will be
triggered continuously until the target disappears.
• Scene Modes: The scene mode is set to be General by default. Select Distant View when you are far from
the targets. Select Leaves Interfered View when there are shaking targets in the scene such as leaves.
Restore Parameters
• Restore Default: Click Restore to restore the parameters to the default.
• Restart VCA: Click Restart to restart the VCA function.