12.9. Set ISUP

When the device is registered on an ISUP platform (formerly called Ehome), you can visit and manage the
device, transmit data, and forward alarm information over a public network.
Steps
1. Go to Configuration → Network → Advanced Settings → Platform Access.
2. Set ISUP as the platform access mode.
3. Select Enable.
4. Select a protocol version and input related parameters.
5. Click Save. Register status turns to Online when the function is correctly set.

12.10. Set ONVIF

To access the device through ONVIF protocol, configure the ONVIF user to enhance the network security.
Steps
1. Go to Configuration → Network → Advanced Settings → Integration Protocol.
2. Check Enable ONVIF.
3. Click Add to configure the ONVIF user.
Delete: Delete the selected ONVIF user.
Modify: Modify the selected ONVIF user.
4. Click Save.
5. Optional: Repeat the steps above to add more ONVIF users.

12.11. Set HTTP Listening

Send alarms via HTTP protocol to a destination IP or host name that supports HTTP data transmission.
Steps
1. Go to Configuration → Network → Advanced Settings → HTTP Listening.
2. Input Destination IP or Host Name, URL, and Port.
3. Click Test.
NOTE:
Click Default to reset the destination IP or host name.
4. Click Save.