HIKVISION DS-2TD6267-75C4L/W User Manual page 17

Thermal & optical bi-spectrum ptz network camera
Hide thumbs Also See for DS-2TD6267-75C4L/W:
Table of Contents

Advertisement

DS-2TD6267-75C4L/W Thermal & Optical Bi-Spectrum PTZ Network Camera User Manual
Emissivity: Set the emissivity of your target. The emissivity of each object is different.
Distance: The distance between the target and the device.
Pre-Alarm Threshold: When the temperature of target exceeds the pre-alarm threshold, and this
status keeps NOT shorter than Filtering Time, it triggers the pre-alarm.
Alarm Threshold: When the temperature of target exceeds the alarm threshold, and this status
keeps NOT shorter than the Filtering Time, it triggers the alarm.
Pre-Alarm Output and Alarm Output: Check Pre-Alarm Output and Alarm Output to set link the pre-
alarm or alarm with the connected alarm device.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting
linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on live view.
Go to Image → VCA Rules Display to adjust the fonts size and the temperature color of
NOTE:
normal, alarm, and pre-alarm.
Set Expert Mode
Select the temperature measurement rules from Point, Line, or Area and configure parameters, the device
alarms if the alarm rules are met.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings, check Enable Temperature
Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings, select Expert.
4. Refer to Set Preset to set a preset.
5. Select and enable the temperature measurement rules. Refer to Set Thermography Rule for setting the
rule.
6. Optional: Click Area's Temperature Comparison to set the alarm rules and the temperature.
7. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting
linkage method.
8. Click Save.
NOTE:
The maximum temperature and thermography rules will be displayed on live view.
Go to Image → VCA Rules Display to adjust the fonts size and the temperature color of
normal, alarm, and pre-alarm.
UM DS-2TD6267-75C4L/W 042221NA