DS-2TD6267-75C4L/W Thermal & Optical Bi-Spectrum PTZ Network Camera User Manual
Measurement+Behavior analysis.
Steps
1. Go to Configuration → Local and select Display Temperature Info. as Yes.
2. Go to Configuration → Temperature Measurement → Basic Settings.
3. Check Enable Temperature Measurement.
4. Click Save.
5. Go to the live view interface and select thermal channel, and click
interface to show the real temperature.
3.4.

Search History Temperature

You can search the history temperature and generate the temperature/time graphic.
Before You Start
Refer to Set Memory Card and Set NAS to set the storage first.
Steps
1. Go to Configuration → Temperature Measurement → Search History Temperature.
2. Set the search parameters.
Preset: You can search the highest temperature information in normal mode, or search the
temperature information of special presets in expert mode.
Start Time: Set the searching start time.
Display Time Interval: Display the temperature information for every setting time interval.
3. Click Search to generate the graphic.
4. Click Export to download the graphic.