DS-2TD6267-75C4L/W Thermal & Optical Bi-Spectrum PTZ Network Camera User Manual

13.8. Set Electric Current Limit

This function can control the power supply current of the device.
Go to Configuration → System → Maintenance → System Service, and select Electric Current Limit type. You
can limit the device current to 75 percent of full current or half the full current for power saving control.

13.9. View Open Source Software License

Go to Configuration → System → System Settings → About Device, and click View Licenses.

13.10. Time and Date

You can configure time and date of the device by configuring time zone, time synchronization, and Daylight
Saving Time (DST).
Synchronize Time Manually
Steps
1. Go to Configuration → System → System Settings → Time Settings.
2. Select Time Zone.
3. Click Manual Time Sync.
4. Choose one time synchronization method.
Select Set Time, and manually input or select date and time from the pop-up calendar.
Check Sync. with computer time to synchronize the time of the device with that of the local PC.
5. Click Save.
Set NTP Server
You can use NTP server when accurate and reliable time source is required.
Before You Start
Set up a NTP server or obtain NTP server information.
Steps
1. Go to Configuration → System → System Settings → Time Settings.
2. Select Time Zone.
3. Click NTP.
4. Set Server Address, NTP Port, and Interval.
NOTE:
Server Address is NTP server IP address.
UM DS-2TD6267-75C4L/W 042221NA