Manual Thermography; Search History Temperature - HIKVISION DS-2TD4238-7/S2 User Manual

Thermal & optical bi-spectrum ptz network camera
Hide thumbs Also See for DS-2TD4238-7/S2:
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
Go to Live View interface to view the maximum temperature and rule of the line in thermal
channel.
Area Thermography
Configure the temperature measurement rule and monitor the maximum temperature of the area.
Steps
1. Click and drag the mouse in the live view to draw the area and right click to finish drawing.
2. Click and move the area to adjust the position.
3. Drag the corners of the area to adjust the size and shape.
Go to Live View interface to view the maximum temperature and rule of the area in thermal
channel.

3.4 Manual Thermography

After enable the manual thermography function of the device, you can click any position on the
live view to show the real temperature.
Steps
1. Go to Configuration → Local and select Display Temperature Info. as Yes.
2. Go to Configuration → Temperature Measurement → Basic Settings .
3. Check Enable Temperature Measurement.
4. Click Save.
5. Go to live view interface and select thermal channel, click
to show the real temperature.

3.5 Search History Temperature

You can search the history temperature and generate the temperature/time graphic.
Before You Start
Refer to Set Memory Card and Set NAS to set the storage first.
Steps
1. Go to Configuration → Temperature Measurement → Search History Temperature .
2. Set the search parameters.
Preset
You can search the highest temperature information in normal mode. Or you can search the
temperature information of special presets in expert mode.
Rule
Select a rule of the special preset.
. Click any position on the interface