Manual Thermography; Search History Temperature - HIKVISION DS-2TD8166-150ZH2F/V2 User Manual

Thermal & optical bi-spectrum ptz network camera
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual

3.4 Manual Thermography

After enable the manual thermography function of the device, you can click any position on the
interface to show the real temperature.
Before You Start
Go to Configuration → System → Maintenance → VCA Resource Type, and select Temperature
Measurement+Perimeter Protection.
Steps
1. Go toConfiguration → Local and select Display Temperature Info. as Yes.
2. Go toConfiguration → Temperature Measurement → Basic Settings.
3. Check Enable Temperature Measurement.
4. Click Save.
5. Go to live view interface and select thermal channel, click
interface to show the real temperature.

3.5 Search History Temperature

You can search the history temperature and generate the temperature/time graphic.
Before You Start
Refer to Set Memory Card and Set NAS to set the storage first.
Steps
1. Go to Configuration → Temperature Measurement → Search History Temperature.
2. Set the search parameters.
Preset
You can search the highest temperature information in normal mode. Or you can search the
temperature information of special presets in expert mode.
Start Time
Set the searching start time.
Display Time Interval
Display the temperature information for every setting time interval.
3. Click Search to generate the graphic.
4. Click Export to download the graphic.