Polycom SpectraLink 6300 MCU Manual page 54

Hide thumbs Also See for SpectraLink 6300 MCU:
Table of Contents

Advertisement

SpectraLink 6300 MCU: Operator's Console: SpectraLink 6000 System
Signal Level Range
-38 to -45 dBm
-46 to -75 dBm
-76 to -102 dBm
54
If signal levels indicate problems, you may need to relocate Base
Stations. For example:
Action
Base Station may be too close to another and is in danger of locking out and
alarming. Move the Base Stations farther apart.
Normal signal level.
Weak signal which may indicate that Base Stations may not be providing
adequate coverage. You may need to rearrange Base Stations by moving
them closer together.
This table is a guideline only. Use the floor plans for the facility as a
guide for planning Base Station moves. Also, coverage may be
designed to serve areas without crossover traffic; therefore even
though Base Stations are far apart, coverage is adequate for user
needs.
Before moving any Base Station, consider what effect the move will
have on other Base Stations that are close by. For instance, if you want
to move one Base Station away from another, you may also be
moving it closer to a third Base Station.
If you relocate Base Stations, review the listen values after all the Base
Stations have completed the listen cycle.
Dump Listen Verify report
The latest Listen Verify report can be copied to a file (lisver.log) in
your working directory. To do this:
1. From the
Supervisor State Display
2. From the menu, select
3. At the prompt, select
(to add to the existing file. You may want to append the file if you
need to compare old and new data.
screen (F1), press Enter.
Dump Listen Verify Report
(to overwrite existing file) or
Replace
and press Enter.
Append