Polycom SpectraLink 6300 MCU Manual page 44

Hide thumbs Also See for SpectraLink 6300 MCU:
Table of Contents

Advertisement

SpectraLink 6300 MCU: Operator's Console: SpectraLink 6000 System
44
of Calls out, Amount of time in use (or in Alarm), Base Station the line
is active on.
Screen displays the following information for each
RCU (Base Stations)
Base Station (RCU): Port #, State, # of Downloads, # of MCU detected
Link errors, # of Base Station detected Link errors, Amount of Time
Full (or in alarm), Lines active on that Base Station.
Alarm and Status information (right-hand columns)
Amount of time the Interface Module has been running.
Uptime
Interface Module state.
MCU State
through
Alarms CT1
DAA 2
If they are in an alarm state, there will be an alarm message or reason
listed next to the component. See SpectraLink 6300 MCU: Maintenance
and Diagnostics for troubleshooting information.
The first number is the maximum number of
CT Max/Full
simultaneous calls on this Interface Module at a given time. Each
Interface Module can handle eight simultaneous calls. The second
number is the number of times the Interface Module's queue was full.
Length of time the Interface Module's queue was full.
CT Full Time
Used by Polycom engineering.
IPC RX CRC
and
Version numbers of the system hardware. These
Brd, ROM, Fac
Dl
are set at the factory.
Software version numbers of the Interface Module.
PC
Software version number of the code loaded on the port card
PT
available for download to the wireless telephones.
Line menu
Highlight any Line on the Interface Module and press Enter to display
a menu of display options for lines:
Displays detailed information about a specific line.
Show Line Detail
See Chapter 3 System Status, section Supervisor State Display (F1).
Clears any alarms associated with a specific line.
Clear Line Alarm
Clear MCU/CT/DAA Alarms
cleared.
Resets the Interface Module (port card). Similar to
Reset Portcard
unplugging and replugging the card.
in normal function.
Running
These are sub-components of the module.
Displays a menu of possible alarms to be
PN: 1725-36125-001_L.doc

Advertisement

Table of Contents
loading

Table of Contents