4-6 Setting Measurement Mode of the Sensor
The sensor has the following two modes:
• Internal synchronous measurement mode
• External syncshronous measurement mode
Internal synchronous measurement mode
A mode to perform measurement at each [Measurement cycle] as set. Used for continuous measurement.
External synchronous measurement mode
A mode to perform measurement according to SYNC/TRIGGER input signals. Used for measurement in
synchronization with external signals.
Item
Setting item
Sensor settings
Measurement
mode
Explorer pane
→ Edit pane
1
Set [Measurement mode].
Important
• Measures one by one input the external Trigger signal in External synchronous measurement mode.
• Need to input the external Trigger signal depending on the setting content of the filtering process.
Example)
When you set the Average number to 128, need the external Trigger signal to input 128 counts.
• When you set the Exposure control mode to Auto, multiple inputs of external Trigger signal are necessary after
adjusting the measurement object within the measurement range for optimization of exposure status.
138
Setting Measurement Mode of the Sensor
Setting value
Internal synchronous measurement mode
(default value)
External synchronous measurement mode
: [System] (double-click)
: [Sensor Settings] icon (
Description
Select the measurement mode for the Sensor
Controller.
)
ZW-7000 User's Manual