The range of cut-off frequency to be effective in operation varies depending on the setting of measurement
cycle.
The relationship between the measurement cycle and the cut-off frequency range is shown in the table below.
Measurement cycle
[μs]
High-pass filter
Band-pass filter
Lower limit
20
1275
40
638
60
425
80
319
100
255
200
128
300
85
400
64
Note
The frequency filter can also be set by the operating keys on the Sensor Controller.
Setting the Frequency Filter p.205
Important
• If a value outside of the appropriate range is set, the frequency filter will be applied with the values included in the
range.
• If the cut-off frequency values (upper/lower limits) are too close, the frequency bandwidth to be detected cannot be
properly detected.
• The sampling frequency is the inverse of the measuring cycle.
Important
Frequency filter is applicable the measurement result executed Trigger input even if select the External synchronous
measurement mode. In this case, the sampling interval of measured result is used the measurement cycle value
which has been set and executed external Trigger input.
The value is not dependent on the interval which is actually executed Trigger input.
ZW-7000 User's Manual
Cut-off frequency range [Hz]
Low-pass filter
Upper limit
Lower limit
23725
20
11862
10
7907
7
5931
5
4744
4
2372
2
1581
1.5
1185
1
Upper limit
23725
11862
7907
5931
4744
2372
1581
1185
Setting the Output Conditions