Advertisement

Item
Setting item
Setting value
Trigger
Trigger level
-999.999999 to 999.999999
Settings
[mm]
(default value: 0)
Trigger hysteresis 0 to 999.999999 [mm]
(default value: 0.05% of
measuring range)
 Explorer pane
→ Edit pane
→ Task Settings window : [Hold]
1
Set the hold mode.
Setting the Hold Mode p.121
2
Select the trigger method from [Trigger
method].
3
Enter [Trigger level] and [Trigger hysteresis]
when [Selfup trigger] or [Selfdown trigger]
are selected at [Trigger method].
Important
Set "Trigger hysteresis" according to the fluctuation of the measured value near the trigger level. Hysteresis is applied
simultaneously with start of measurement to prevent chattering of the TIMING input.
Note
The trigger can also be set by the operating keys on the Sensor Controller.
Setting Triggers p.212
ZW-7000 User's Manual
Description
Set the self-trigger level when [SELF-UP] or [SELF-DOWN] are selected at
[Trigger method].
Set the hysteresis width for the self-trigger when [SELF-UP] or [SELF-
DOWN] are selected at [Trigger method].
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
)
Setting the Output Conditions