Omron ZW-XC7 User Manual page 159

Confocal fiber type displacement sensor
Table of Contents

Advertisement

LOGERR signal is turned ON at the following cases:
• Overwrite mode is OFF
• 2,000,000 items have already logged in the internal memory at the begging of logging.
When continue to logging regardless number of logging while LOGGING input signal is turned ON, set
as below:
• Number of logging data: 0
• Overwrite mode: ON
When the number of loggings reaches 2,000,000, past logging data is overwritten and logging continues
on the latest data.
2
Set the output conditions of internal logging data.
Set the conditions for the external output using the non-procedural command LO.
Item
Setting item
Internal logging
Output data
setting
format
Note
For the response format of LO commands according to the output data format, refer to following page.
"5-1 Connecting by No-protocol Communications" described in Displacement Sensor ZW-7000
series Confocal Fiber Type Displacement Sensor User's Manual for Communications Settings
(Z363-E1-01)
ZW-7000 User's Manual
Setting value
Description
ASCII (default value)/
Select the output format for outputting internal logging data.
Binary
Performing internal logging
157