Performing Calculations

Perform calculations using the results calculated by the tasks. The calculation formula is mX+nY+K.
Item
Setting item
Calculation
Parameter X
Parameter Y
Parameter K
Parameter m
Parameter n
 Explorer pane
→ Edit pane
→ Task Settings window : [Measurement mode]
Select [Calculation] in [Measurement mode].
1
Select [Calculation] in [Measurement mode].
2
Select the task to be calculated from
[Parameter X] and [Parameter Y].
3
Select the offset value from [Parameter K].
4
Select the coefficient from [Parameter m]
and [Parameter n].
Note
Performing Calculations can also be set by the operating keys on the Sensor Controller.
Calculating p.200
Important
Calculates using the measurement value of the last TASK.
The timing to update the measurement value of TASK is shifted one cycle by comparing the update timing of the
measurement result of reference TASK.
Example)
TASK1: Height (Edge1)
TASK2: Height (Edge1)
TASK3: Calculation (X: TASK1, Y: TASK2, M: 1.9, K: 0.0)
Measurement count
TASK1
1st
0.200
2nd
0.310
ZW-7000 User's Manual
Setting value
OFF (default value)/TASK1 to TASK4
OFF (default value)/TASK1 to TASK4
-999.999999 to 999.999999
(default value: 0)
-10.0 to 10.0 (default value: 0)
-10.0 to 10.0 (default value: 0)
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
TASK2
TASK3
0.100
0.000
0.110
0.100 *Calculates using 1st result of TASK1 and TASK2.
Description
The task to be calculated can be switched.
When the TASK1 is selected, TASK1 is not
displayed in the setting item.
The task to be calculated can be switched.
When the TASK1 is selected, TASK1 is not
displayed in the setting item.
Set the offset value.
Set the coefficient value.
Set the coefficient value.
)