Front view
l Display
No.
Names (light color)
1
HIGH indicator (orange)
2
PASS indicator (green)
3
LOW indicator (orange)
4
STABILITY indicator (green)
5
ZERO indicator (green)
6
ENABLE indicator (green)
7
Main display (white)
8
Sub-display (green)
9
RUN indicator (green)
10
THRESHOLD-L indicator
(orange)
11
THRESHOLD-H indicator
(orange)
12
ECAT RUN indicator (green)
13
L/A IN indicator (green)
14
L/A OUT indicator (green)
15
ECAT ERROR indicator (red)
l Control panel
No.
Names
16
ZERORST/ESC key
← (LEFT) key
17
→ (RIGHT) key
↑ (UP) key
↓ (DOWN) key
18
ZERO/SET key
19
Mode switching key
20
Node address setting switches
(hexadecimal representation)
ZW-7000 User's Manual
Functions
The HIGH indicator is lit while judgment is resulted in HIGH (HIGH threshold value <
measured value).
The PASS indicator is lit while judgment is resulted in PASS (LOW threshold value ≤
measured value ≤ HIGH threshold value).
The LOW indicator is lit while judgment is resulted in LOW (measured value < LOW
threshold value).
The STABILITY indicator is lit while the measurement area 1 is within the measuring
range.
It goes out if a measured value is out of the measuring range.
The Zero Reset indicator is lit while the zero reset function is enabled.
The ENABLE indicator lights when the Sensor is ready for measurement.
It goes off when measurement is not possible (e.g. when the received light amount is
excessive or insufficient, when the calibration ROM is not connected, or when
measurement is not being performed in FUNC mode).
The main display shows measured values and/or function names.
The sub-display shows additional information for measured values or setting values for
functions.
The RUN indicator is lit in the RUN mode, and goes out in the FUNC mode.
The LOW threshold value indicator is lit when the Sub-display indicates a LOW threshold
value.
The HIGH threshold value indicator is lit when the Sub-display indicates a HIGH threshold
value.
ECAT RUN indicator lights up when EtherCAT communication is established.
L/A IN indicator lights up when connected with the EtherCAT device.
Flashes when communication (data input) is performed.
L/A OUT indicator lights up when connected with the EtherCAT device.
Flashes when communication (data output) is performed.
ECAT ERROR indicator lights up when an EtherCAT communication error occurs.
Functions
These keys function differently depending on operation modes.
8-2 Functions of Operating Keys p.185
These switches are used to set the node address as an EtherCAT communications
device.
The setting range is 0x01(1) to 0xFF(255).
Part Names and Functions
45