Serial Trigger; Read Time-Out - Honeywell Xenon Series User Manual

Area-imaging scanners
Table of Contents

Advertisement

Trigger Toggle Timeout
This sets the length of time the scanner stays in trigger toggle mode before revert-
ing to scan mode. After scanning the Trigger Toggle Timeout bar code, set the
time-out duration (from 0 to 65 seconds) by scanning digits from the
Programming Chart,
Note: If this is set to 0, you must repeat the toggle sequence to return to the default
scanning mode. For example, if 2 quick trigger presses puts the scanner into cell
phone read mode and the Trigger Timing is 0, you would have to do 2 quick presses
again to go back to the default scanning mode.

Serial Trigger

You can activate the scanner either by pressing the trigger, or using a serial trigger
command (see
mode in order to use serial triggering. Refer to
Serial
until a bar code has been read or until the deactivate command is sent. The scan-
ner can also be set to turn itself off after a specified time has elapsed (see
Time-Out, which follows).

Read Time-Out

Use this selection to set a time-out (in milliseconds) of the scanner's trigger when
using serial commands to trigger the scanner. Once the scanner has timed out, you
can activate the scanner either by pressing the trigger or using a serial trigger
command. After scanning the Read Time-Out bar code, set the time-out duration
(from 0-300,000 milliseconds) by scanning digits from the
beginning on page 353, then Save. Default = 30,000 ms.
Xenon/Granit User Guide
beginning on page 353, then Save. Default = 5 seconds.
Trigger Commands
(page 21) for further information. When in serial mode, the scanner scans
Trigger Toggle Timeout
on page 270). You must be in a serial interface
RS232 Serial Port
Read Time-Out
(page 18) or
USB
Read
Programming Chart,
121