Honeywell Xenon Series User Manual page 164

Area-imaging scanners
Table of Contents

Advertisement

The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFFSEQSEP993C3ESEQSUF990D0
ASEQTTS1SEQISU993E5041525449414C3C
The data is output as:
>PARTIAL<
<TSTMSGCODE128>
<MSGPDF417>
Discard Partial Output Sequence
If you want to discard partial sequences when the output sequence operation is
terminated before completion, scan Discard Partial Sequence.
Default Output Sequence
Default Sequence programs the scanner to all universal values. Be certain you
want to delete or clear all formats before you read the Default Sequence symbol.
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device. When
it's On/Not Required, the scanner will attempt to get the output data to conform to
an edited sequence but, if it cannot, the scanner transmits all output data to the
host device as is, or formatted according to the partial sequence output format
(see
When the output sequence is Off, the bar code data is output to the host as the
scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
144
49
41
4C
3C
Partial Sequence
on page 142).
I
A
L
left bracket (<)
* Discard Partial Sequence
Default Sequence
Xenon/Granit User Guide

Advertisement

Table of Contents
loading